Miner comparison
Antminer S23 XP Hyd. vs Antminer S23 Hyd.
Both are hydro-cooled (liquid-cooled) Bitmain Antminer S23 models for SHA-256 (Bitcoin) mining. They share a three-phase 380–415 V AC supply drawing up to 12 A and the same coolant requirements: 20–50 °C at the inlet, 8.0–10.0 L/min, at most 3.5 bar, with OD10 pipe connectors. Bitmain rates the S23 XP Hyd. at 600 TH/s on 5,340 W (8.9 J/TH) and the S23 Hyd. at 580 TH/s on 5,510 W (9.5 J/TH), both at 35 °C inlet coolant. The XP gives about 3% more hashrate on about 3% less power, so each terahash takes about 6% less electricity. The housings are close in size (409 × 176 × 208 mm against 410 × 170 × 209 mm); the XP is heavier, at 15.8 kg net against 13.5 kg. Bitmain gives no noise figure for either. The table below and the calculator work out what these figures mean with current network data.
Figures: Bitmain specification pages for Antminer S23 XP Hyd. and Antminer S23 Hyd., checked 2026-10-10.
| Compare | ![]() Bitmain Antminer S23 XP Hyd.Available | ![]() Bitmain Antminer S23 Hyd.Available |
|---|---|---|
| Price | ||
| Price | $14,535 | $11,684.05 |
| Price per TH/s | $24.23/TH | $20.14/TH |
| Condition | New | New |
| Specifications | ||
| Hashrate | 600 TH/s (±3%) | 580 TH/s (±3%) |
| Power consumption | 5,340 W (±5%) | 5,510 W (±5%) |
| Efficiency | 8.9 J/TH | 9.5 J/TH |
| Algorithm | SHA-256 | SHA-256 |
| Input voltage | 380–415 V AC | 380–415 V AC |
| Electrical phase | Three-phase | Three-phase |
| Cooling type | Hydro-cooled | Hydro-cooled |
| Coolant inlet temperature | 20–50 °C | 20–50 °C |
| Coolant flow | 8–10 L/min | 8–10 L/min |
| Dimensions (L × W × H) | 409 × 176 × 208 mm | 410 × 170 × 209 mm |
| Net weight | 15.8 kg | 13.5 kg |
| Operating economics | ||
| Electricity cost / day at $0.06/kWh | $7.69 | $7.93 |
| Est. revenue / day | $21.30 | $20.59 |
| Est. net / day at $0.06/kWh | $13.61 | $12.66 |
| Break-even electricity price | $0.166/kWh | $0.156/kWh |
Green marks the better value in a row (higher hashrate; lower power, J/TH, noise, weight, price and electricity cost). Specifications are as recorded for each product; “—” means the value is not stated. Economics are estimates at network conditions of 2026-10-28, $0.06/kWh, 2% pool fee and 100% uptime, and are not a forecast of earnings.
Go further
Want a different pair? Build your own comparison.

Wholesale & project supply
Deciding between models for a larger order?
Send both models and your quantity. Sales quotes each option with current batch availability and freight so you can compare landed cost.